Baseline Systems Baseline BFM Series Flow Meter User Manual

Baseline bfm series flow meters installation guide

Advertising
background image

Baseline BFM Series Flow Meters

Installation Guide

1-866-294-5847

Rev 11042013

www.baselinesystems.com

Installation Instructions

1. Power off the two-wire when installing any two-wire device. Leave 24 to 36 inches of slack in

the two-wire at the connection point to allow for easy installation and maintenance.

2. Follow the instructions in the Netafim installation manual to install the flow meter.

3. Connect the red and black wires from the flow biCoder to the corresponding red and black

wires from the two-wire path. Make certain to maintain polarity. All two-wire connections
must have DBR/Y or equivalent moisture-resistant connectors.

4. Follow the instructions in the controller’s user manual to configure each device.

Always use appropriate

moisture-resistant connectors

Connect the red wire from the

biCoder to the red wire on the

two-wire path. Do the same

for the black wires.

Flow biCoder that is attached

to the flow meter

K Value and Offset Table

Model

Gallons per Pulse

Pulses per Gallon

K-Value

Offset

Suggested Operating Range (GPM)

BL-BFM075

0.015

666.67

0.09

0

0.2-11

BL-BFM100

0.0021

476.19

0.126

0

0.3-15.4

BL-BFM150

0.0074

135.14

0.444

0

0.9-44