Basement Watchdog Greenline BW Series User Manual

Basement Watchdog Pumps

Advertising
background image

Specifications

1/3 HP Model BW1033

1/2 HP Model BW1050

GPH @ 0’

3600

4400

GPH @ 10’

2600

3200

G/Wh

6.2

6.3

Pump diameter

6.2”

6.2”

Volts

115V, 60Hz

115V, 60Hz

Amps

3.5

4.2

Important Safety Instructions

SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to
it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.

ALWAYS disconnect the pump from the power source before servicing or making

adjustments.

NEVER handle the pump or motor with wet hands or when standing on a wet or damp

surface while the pump is plugged into the power source.

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is

wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.

NEVER bypass grounding wires or remove the ground prong from the plug.

DO NOT use an extension cord. The electrical outlet should be within the length of the

pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.

DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.

Avoid kinking the cord.

MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power

requirements noted on the nameplate of the pump.

DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.

DO NOT expose the control unit to rain or snow.

DO NOT operate the pump or control unit if it has been damaged in any way.

DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.

DO NOT disassemble the pump or control unit. When service is required, contact

Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:

Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069

ƽ CAUTION

ƽ WARNING

Risk of electric shock. To reduce this risk, observe the
following precautions
.

To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.

Basement Watchdog

Sump Pumps

Instruction Manual &

Safety Warnings

Items Included:

Pump

Dual float and controller

Stainless steel hose clamp

You may also need:

A 1-1/2” PVC pipe adapter to screw
into the discharge hole on top of
the pump

1-1/2” rigid PVC pipe to connect
to the existing plumbing

A check valve or rubber union

PVC pipe cleaner and cement

Wire ties or hose clamps

The Dual Float

& Controller

1/2 HP Pump

BW1050

1/3 HP Pump

BW1033

Models

BW1033

and

BW1050

G/Wh = Gallons per Watt Hour G/Wh = GPH/(Amps x Volts)