Choose the flash mode for the built-in flash in P, S, A, and M modes.

Built-in Flash

G button

➜ C shooting menu

Option

Description

1 TTL

Flash output is adjusted automatically in response to shooting conditions.

2 Manual

Choose a flash level between Full and 1/32 (

1

/

32

of full

power). At full power, the built-in flash has a Guide
Number of 13/43 (m/ft., ISO 100, 20 °C/68 °F).

A

Manual

A

Y icon blinks in the viewfinder and information display when

Manual is selected and the flash is raised.

A

The SB-400

When an optional SB-400 flash unit is attached and turned on, Built-
in flash
changes to Optional flash, allowing the flash control mode
for the SB-400 to be selected from TTL and Manual.

A

Flash Control

The following types of flash control are supported when a CPU lens is used in combination
with the built-in flash or optional SB-900, SB-800, SB-600, and SB-400 flash units (

0 58, 162).

• i-TTL Balanced Fill-Flash for Digital SLR: Flash output is adjusted for a natural balance between

the main subject and the background.

• Standard i-TTL Fill-Flash for Digital SLR: Flash output is adjusted for the main subject; the

brightness of the background is not taken into account. Recommended for shots in which
the main subject is emphasized at the expense of background details, or when exposure
compensation is used.

Standard i-TTL flash control is used with spot metering or when selected with the optional
flash unit. i-TTL balanced fill-flash for digital SLR is used in all other cases.