Using the graphic eq and effect libraries, Geq library, Effect library – Yamaha LS9 User Manual

Page 174: P. 174)

Advertising
background image

174

Using the graphic EQ and effect libraries

LS9-16/32 Owner’s Manual

You can use dedicated libraries to store and recall graphic EQ and effect settings.

Use the “GEQ library” to store and recall GEQ settings.
This GEQ library can be referenced by all GEQ units used
in the LS9. (However, the 31 Band GEQ and Flex15GEQ
are different types. You cannot recall a GEQ library item
of a different type.)
200 items can be recalled from the library. Number 000 is
read-only, and the remaining library numbers can be
freely read or written.

To access the GEQ library, move the cursor to the LIB
toolbutton in the upper part of the screen when a GEQ is
shown in the RACK screen, and press the [ENTER] key.

1

LIB button

For details on using the library, refer to “Using libraries”
(

→ p. 35).

Use the “Effect library” to store and recall effect settings.
199 items can be recalled from the effect library. Library
items 1–48 are read-only presets, and correspond to effect
types 1–48 respectively. Library items 49–57 are reserved
for use by the system. Other library item numbers can be
freely read and written.

To access the effect library, move the cursor to the LIB
toolbutton in the upper part of the screen when an effect is
shown in a RACK 5–8 screen, and press the [ENTER]
key.

1

LIB button

For details on using the library, refer to “Using libraries”
(

→ p. 35).

Using the graphic EQ and effect libraries

GEQ library

1

• Store/recall operations are performed on individual racks. You

can’t individually store/recall two Flex15GEQ units that are
mounted in the same rack.

NOTE

Effect library

1

• Library items using the “HQ.PITCH” or “FREEZE” effect types can

be recalled only into rack 5 or 7. They cannot be recalled into rack
6 or 8.

NOTE

• You can also use MIDI messages (program changes) to recall

effect settings from the library (

p. 180).

HINT

Advertising