– 19 –

Battery charging

Do not connect a VRLA (Valve Regulated Lead
Acid) battery. To charge a VRLA battery, a special
(constant-voltage) battery charger is required.

TIP

9 The generator DC rated voltage is 12V.
9 Start the engine first, and then connect the gener-

ator to the battery for charging.

9 Before starting to charge the battery, make sure

that the DC protector is turned on.

1. Start the engine.

NOTICE

762-040

1

2

6v

6v

12v

762-041

2. Connect the red battery charger lead to the posi-

tive (+) battery terminal.

1 Red wire
2 Black wire

3. Connect the black battery charger lead to the neg-

ative (-) battery terminal.

4. Turn the economy control switch off to start battery

charging.

7DK-9-11_a 11.3.21 15:19 Page 19