Power Circuit Test
at Key Switch—
Fuse Side

Turn key switch to RUN
position.

M55141 -UN-09DEC89

Check for voltage at
key switch terminal “A”,
where red and pink
wires (A) connect to
key switch.

VOLTAGE:
For 20-amp power
circuit, pink wire
between fuse and key
switch is open.

For 2-amp or 3-amp
power circuit, red wire
between fuse and key
switch is open.

Repair or replace wire
as necessary, then GO
TO

;

and

Å

, Group 05.

NO VOLTAGE: GO TO

1f

1f

Power Circuit Test
at Key Switch—
Battery Side

Key switch OFF.

M55142 -UN-09DEC89

Check for voltage at
key switch terminal “B”
where red wire (A) from
circuit breaker
terminates.

VOLTAGE: Replace
key switch.

NO VOLTAGE: GO TO

1g

1g

Main Power
Circuit Test at
Circuit Breaker

Check 20-amp fuse.

If fuse is OK, remove
battery base to access
circuit breaker.

Set battery on air
cleaner cover, then
reroute negative (—)
cable to connect
battery.

M37158 -UN-25JAN90

NOTE: Early Models:
316 (S.N. —362983)
318 (S.N. —364137)
420 (S.N. —360009)
have starter soleniod
mounted next to
circuit breaker, as
shown.

On Later Models;
Starter solenoid is
on starter.

Check for voltage at
both terminals (A) of
circuit breaker.

VOLTAGE AT ONLY
ONE TERMINAL:
Replace breaker.

VOLTAGE AT BOTH
TERMINALS: Red wire
between key switch and
circuit breaker is open.
Repair or replace as
necessary, then GO TO

;

, Group 05.

NO VOLTAGE AT
EITHER TERMINAL:
For early machines, GO
TO

1h

.

For later machines,
replace red wire to
battery.

MX,159024025,15-19-16MAY95