Starter Circuit
Test at PTO Switch

Turn key switch to RUN
position.

M55146 -UN-11DEC89

Check for voltage at
terminal (A) with yellow
and purple wires, then
at terminal with single
purple wire.

VOLTAGE ONE
TERMINAL: Replace
switch.

VOLTAGE BOTH
TERMINALS: Purple
wire between jumper
connector and PTO
switch is open.

NO VOLTAGE: GO TO

1e

Repair or replace wire,
then GO TO

, Group

05.

Æ

IGNITION CIRCUIT
TESTS

Listed at right are
symptoms that may
occur in a
malfunctioning ignition
circuit. Locate the
symptom that applies,
then proceed to the
appropriate test.

IGNITION CIRCUIT SYMPTOMS:

—Starter Cranks Engine
Satisfactorily, But Engine
Doesn’t Start: GO TO

3a

—Engine Stops With Operator
On Seat When:
PTO Switch Is Turned On,
Or
Hydrostatic Lever Is Moved
To Forward Or Reverse Position,
Or
Brake Pedal Is Released
(Later Machines Only).
GO TO

4e

—Engine Starts, But Misfires:
For Machines (S.N. —420000);
GO TO

3j

For Machines (S.N. 420001— );
GO TO

3k

3a

Ignition Circuit
Test—All Machines

PTO switch OFF.

Hydrostatic lever in
N/STOP position.

NOTE: Engaged park
brake required on
machines:
316 (S.N. 596121— )
318 (S.N. 600305— )
420 (S.N. 595881— )

Engage park brake.

M55081 -UN-17JAN95

Remove right-hand
engine side panel.

Disconnect engine 3-pin
connector.

Turn key switch to RUN
position.

Check for voltage at
pink wire terminal of
connector (A).

VOLTAGE:

For Machines
(S.N. —420000);
GO TO

3b

For Machines
(S.N. 420001— );
GO TO

3f

NO VOLTAGE:
GO TO

3l

MX,159024025,39-19-16MAY95

MX,159024025,40-19-16MAY95

MX,159024025,41-19-16MAY95

Electrical System Diagnosis/Ignition Circuit Tests