John Deere 318 User Manual

Page 343

Advertising
background image

3a

Bendix Starter—
No Load Running
Test

M37208 -UN-25JAN90

Disconnect battery
ground cable.

Remove starter and
mount in a vise.

Connect jumper cables
from starter to machine
battery or battery of
similar capacity.

Connect positive clamp
to starter positive (+)
terminal (A).

Connect negative (—)
battery cable (B) to
starter body.

Starter should run.

STARTER DOESN’T
RUN: Repair starter.
(See CTM2.)

STARTER RUNS: GO
TO

3b

3b

Bendix Starter—
No Load RPM
Test

M37203 -UN-25JAN90

Mount starter in a vise
and connect to a
battery as instructed in

3a

With starter running,
check no load rpm with
a tachometer such as
JT05719. (Follow
manufacturer
instructions with the
tachometer.)

No load rpm should be
about 5900.

RPM NO LESS THAN
5900: GO TO

3c

RPM BELOW 5900:
Make sure battery is of
proper rating size and
fully charged. If not,
repeat test as needed
with proper size battery
that’s fully charged.

If battery is OK, repair
or replace starter. (See
CTM2.)

3c

Bendix Starter—
No Load Amp
Draw Test

M37204 -UN-25JAN90

Mount starter in a vise
and connect to a
battery as instructed in
step

3a

With starter running,
check amperage with
JT05712 Current Gun
(A).

Starter should draw 30
amps or less at 5900
rpm.

AMPERAGE 30 OR
LESS: Starter OK.
Malfunction is in wiring
on machine. Check all
connections and
grounds.

AMPERAGE MORE
THAN 30: Repair or
replace starter. (See
CTM2.)

MX,159024030,6 -19-16MAY95

MX,159024030,7 -19-16MAY95

MX,159024030,8 -19-16MAY95

Electrical System Component Tests and Adjustments/Starter Tests

TM1590 (17MAY95)

240-25-3

316, 318 & 420 Lawn and Garden Tractors

020895

240

25

3

Advertising
This manual is related to the following products:

316, 420