SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Compressor not running.

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit

breaker.

Power cord unplugged.

Plug in power cord.

Thermostat set too high.

Set thermostat to lower

temperature.

Cabinet in defrost cycle.

Wait for defrost cycle to finish.

Condensing unit runs for

Excessive amount of warm product

Allow adequate time for

long periods of time.

placed in cabinet.

product to cool down.

Prolonged door opening or door ajar.

Ensure doors are closed when

not in use. Avoid opening

doors for long periods of time.

Door gasket(s) not sealing properly.

Ensure gaskets are snapped in

completely. Remove gasket

and wash with soap and water.

Check condition of gasket and

replace if necessary.

Dirty condenser coil.

Clean the condenser coil.

Evaporator coil iced over.

Unplug unit and allow coil to

defrost. Make sure thermostat

is not set too cold. Ensure that

door gasket(s) are sealing

properly.

Cabinet temperature is

Thermostat set too warm.

Set thermostat to lower

too warm.

temperature.

Blocking air flow.

Re-arrange product to allow for

proper air flow. Make sure

there is at least four inches of

clearance from evaporator.

Excessive amount of warm product

Allow adequate time for

placed in cabinet.

product to cool down.

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit

breaker.

Dirty condenser coil.

Clean the condenser coil.

Prolonged door opening or door ajar.

Ensure doors are closed when

not in use. Avoid opening

doors for long periods of time.

Evaporator coil iced over.

(see above)

Cabinet is noisy.

Loose part(s).

Locate and tighten loose

part(s).

Tubing vibration.

Ensure tubing is free from

contact with other tubing or

components.