CH Tech Pulse Amplifier M206 User Manual

M206 pulse amplifier, M module compliance, Applications

Advertising
background image

C&H

Technologies, Inc.

445 Round Rock West Drive

Round Rock, TX 78681-5012

(512) 733-2621

FAX (512) 733-2629

www.chtech.com


Inputs/Outputs:

Pulse Input

True Output A

True Output B

Complement Output A

Complement Output B

External Power (+36V)

External Power Interlock

Pulse Interlock


External Power:
36V 2A supply required

Front Panel Connectors:
Pulse Input/Outputs

SMA

Ext. Pwr. & Interlocks 9-pin DSUB

Temperature:
Operating:

0

°

C to 50

°

C

Storage:

-40

°

C to 70

°

C


Power (typical):
+5V

150

mA

+12V

300

mA

-12V

100

mA

Ext. +36V

1.0 A

M Module Compliance


Complies with ANSI/VITA Std. 12-
1996 for triple-wide MA Modules
Data Transfers:

16 bit

Interrupts:

not supported

Triggers:

not supported

Compatible with VXI, VME, PCI,
cPCI and other M Module carriers.

Applications

Pulse amplification

Pulse level shifting

Ordering Information


Part Number

11028470-0001

Additional Information


User Manuals for C&H carriers and
this module can be found on our
website at www.chtech.com.

Specifications:


Outputs:
Two true (A & B) and two

complement (A & B) outputs


Frequency:
20MHz

max.


Input: TTL

Output Amplitude:
R

LOAD

= 50

+0.21V to +15V

R

LOAD

=

+0.42V to +30V


Output Current:
Source

300mA

Sink

100mA


Output Impedance: 50


Programming Resolution:
10V

range

2.50mV

30V

range

7.50mV


Accuracy:

±

0.75%

±

75mV


Rise/Fall Time:

30V,

R

LOAD

=

30ns

M206
Pulse Amplifier


The M206 is a programmable pulse
amplifier that accepts a fixed level
input pulse and provides dual
complementary switched outputs.

The module produces a total of four
outputs. Two outputs have the
same active-level as the input pulse
and two outputs have the
complement level of the input pulse.
The output level is programmable
up to 30V into no load (up to 15V
into a 50

load). An external +36V

supply is required. An external
power interlock and a pulse interlock
are provided.

Advertising