FRIGIDAIRE FGHG2366PF User Manual

Service data sheet, Caution, Freezer ice maker information

Advertising
background image

SERVICE DATA SHEET

A01544701

FREEZER ICE MAKER - AUTOMATIC DEFROST

BOTTOM FREEZER - R134a

POWER

ICE MAKER

I

CE

M

AKER

ICE
M

AKER

WATER

VAL
VE

LINE

THERMAL

CUT-OUT

HOLD

SWITCH

THERMOSTAT

SHUTOFF

SWITCH

WATER FILL

SWITCH

MOLD HEATER

MOLD

MOUNTING

PLATE

165 WATTS

MOTOR

NEUTRAL

BLK

BLK

BLK

BLU

C

C

C

NO

NO

NO

NC

NC

NC

YELLOW

BRN

RED

GRN / YEL

RED

RED

LT. BLUE

P-3

P-1

P-2

P-4

ICE MAKER

LT.
BLUE

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons should

not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing

this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position

and properly secured.

SYSTEM DIAGNOSTIC MODE

Activate:

Press FZ ٨ and FZ ٧ for up to 10 sec. simultaneously. Press FF ٨ to advance through tests.

Deactivate:

Press FF ٨ for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.

Note: Silence alarm.

• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.

• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.

• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.

• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.

Test

To activate test:

Passing result

--

First Screen

--

Blank UI display, no lights illuminated, no shadowing.

--

Second Screen

--

All LED lights on UI illuminated.

--

Third Screen

--

Blank UI display, no lights illuminated, no shadowing.

2

Defrost Heater

Press power on-off

Defrost heater on when “on”; off when “off”.

3*

FF Light

(Incandescent

Models)

Press power on-off

FF lights on when “on”; off when “off”

9*

FZ Light

(Incandescent

Models)

Press power on-off

FZ lights on when “on”, off when “off”

12

VCC Condenser Fan Press power on-off

Fan running when “on”; stopped when “off”

13* FF Light

(LED Models)

Press power on-off

FF lights on when “on”; off when “off”

38

VCC Compressor

Press power on-off

Compressor running when “on”; stopped when “off”

15 Evaporator Fan

Press power on-off

Stopped when “off”. Listen for speed change from “LO” to “HI”.

20* FZ Light

(LED Models)

Press power on-off

FZ lights on when “on”, off when “off”

22

Damper

Press power on-off

With inspection mirror, observe damper open when “OP”; closed when “CL”

23

FF Door

Open/close FF door

“CL” on UI when door closed; “OP” when open

24

FZ Door

Open/close FZ door

“CL” on UI when door closed; “OP” when open

29

FF Thermistor

Activates automati-

cally

UI shows temperature sensed by FF thermistor; pass if within 10°F of

temperature measured with gauge at FF thermistor location.

“OP” if open; “SH” if short

30

FZ Thermistor

Activates automati-

cally

UI shows temperature sensed by FZ thermistor; pass if within 10°F of

temperature measured with gauge at FZ thermistor location.

“OP” if open; “SH” if short

33

Ambient Thermis-

tor @ Main Board

Activates automati-

cally

UI shows temperature sensed at main board; pass if within +20°F/-

10°F of temperature measured with gauge at main board location.

“OP” if open; “SH” if short

39

Evaporator

Thermistor

Activates automati-

cally

UI shows temperature sensed by evaporator thermistor; pass if within

10°F of temperature measured with gauge at evaporator thermistor

location. “OP” if open; “SH” if short

34* Ambient Thermis-

tor @ UI

Activates automati-

cally

UI shows temperature sensed at UI; pass if within +20°F/-10°F of

temperature measured with gauge at UI location. “OP” if open; “SH”

if short

0-

Firmware

Parameters

Press power on-off

Displays digit sequence; record

2-

Main Board

Firmware

Press power on-off

Displays digit sequence; record

4-

UI Firmware

Press power on-off

Displays digit sequence; record

ERROR CODES

SPECIAL MODES

Display

Interpretation

Mode

Display

Activate/Deactivate

(press for up to 10 sec. simultaneously)

FZ

FF

FZ

FF

--

OP

Open FF Thermistor

Manual Defrost

d

F

FF ٨ and FF ٧ / same to deactivate

OP

--

Open FZ Thermistor

Display/

Showroom

77

77

FZ ٨ and FF ٧ / Power-on-Reset (POR)

--

SH-

Sabbath

Sb

Sb

FZ ٧ and FF ٨ / same to deactivate

SH

--

Shorted FZ

Thermistor

System

Diagnostic

No FF or FZ display,

all UI LEDs on.

FZ ٨ and FZ ٧ / FF ٨ to deactivate

SY

CF

UI to Main Control

Board communication

failure; on start up

Notes:

• Always check for pin back-outs, pinched or damaged wires before

replacing components.

• Determine whether failure is caused by the component, main control board or

wiring. Contact TID before replacing main control board.

• Refer to Service Manual for additional information.

SY

CE

UI Main Control

Board communica-

tion error;

after a period

in operation

SY

EF

Evaporator fan failure

Variable Capacity Compressor (VCC) Diagnostics (select models)

If test 38 fails, diagnose as follows:

Replace Inverter Board

Check at Inverter Board on

Compressor

(BLK and RED wires)

Is Inverter Board receiving 10-15

VAC and 1-5 VDC from Main

Control Board?

Check at Main Control Board

(BLK/WHT and RED/BLK wires)

Is Main Control Board sending

10-15 VAC and 1-5 VDC to

Inverter Board?

no

Check at the connector from the power cord

harness into the inverter board, located in

the machine compartment.

(PUR and WHT wires)

Is Inverter Board receiving 115 VAC

from power supply?

Check voltage supply.

Check and repair power

cord harness wiring and

connections.

no

Identify and repair damaged wires or

poor connections between Main Control

Board and Inverter Board.

yes

Remove inverter box from the

compressor and check resistance

across compressor winding pairs as

shown.

Is resistance across all winding

pairs equal?

Replace Compressor and

Inverter Board.

no

Check connections from Inverter

Board to Compressor

Are connections from Inverter

Board to Compressor intact?

yes

Identify and repair damaged

wires or poor connections

between Inverter Board and

Compressor.

no

VCC Resistance Check
Check resistance between terminals 1 and

2, 2 and 3, 3 and 1.

If all resistances are equal,

compressor is operative.

Replace Main Control Board.

no

yes

yes

yes

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

TU

R

N

Mounting
Plate
Screws

Mounting
Plate
Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°

CONTROL SETTING

Type A with Run / Start

Capacitor

65°F (18°C) Ambient

90°F (32°C) Ambient

Operating Time

90 to 100%

100%

Freezer Temperature

-5° to 2°F

(-20° to -17°C)

-1° to 3°F

(-18° to -16°C)

Refrigerator Temperature

34° to 39°F

(1° to 4°C)

34° to 39°F

(1° to 4°C)

Low Side Pressure

-2 to 6 psig

(-14 to 41 kPa)

-2 to 6 psig

(-14 to 41 kPa)

High Side Pressure

(last 1/3 cycle)

85 to 105 psig

(586 to 724 kPa)

120 to 135 psig

(827 to 931 kPa)

Wattage (last 1/3 cycle)

30 to 50

50 to 70

Amps (running)

.4 to .8

.7 to .9

Base Voltage

115 vac (127 vac max)

DEFROST SPECIFICATIONS

Cabinet Size:

27’ & 28’ SD, 22’ CD

Thermal Cutout

Heater

Defrost

Heater

Termination

Cut-in

Cut-out

Watts

Ohms

Cut-out

110°F

(43.3°C)

135°F

(57.2°C)

500

26.5

39°F

(4°C)

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

CONDENSER FAN MOTOR

Watts

RPM

Amps

3.1

1100 CW

Opposite Shaft

0.03 Running

FREEZER ICE MAKER SPECIFICATIONS

Electrical

115 vac (127 vac max)

Thermostat

Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)

Heater Voltage

115 vac

CAUTION

All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch

insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the

plastic liner.

FREEZER ICE MAKER INFORMATION

(Where Applicable)

Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use

screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice

maker should function to complete the cycle.

Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc

(.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume

must be checked.