Installation Instructions

2009 Electrolux Home Products, Inc.

All rights reserved.

Installation Instructions

EXAUSTING HOT AIR

1. Take the hose out from back of the unit (Fig. 3).
2. Remove adaptor A from unit by sliding sideways (Fig. 4 ).
3. Extend either side of the hose (Fig. 5) and screw the hose to
adaptor A (Fig. 6) .
4. Extend the other side of the hose and screw it to adaptor B (Fig. 7).
5. Slide the assembly onto unit (Fig. 8).
6. Affix the adaptor B into the window slider kit and seal. (Fig. 9&10)

In the COOLING Mode the appliance must be placed close to a window or
opening so that the warm exhaust air can be ducted outside.

First position unit on a flat floor and make sure there’s a minimum of 12"
clearance around the unit, and is within the vicinity of a single circuit outlet
power source.

The hose can be extended from its original length of 15" up to 55", but it is
the best to keep the length to minimum required. Also make sure that the
hose does not have any sharp bends or sags. (Fig. 11)

Fig. 9

Window Slider Kit
Minimum:26.6"(67.5cm)
Maxmum:48.5"(123cm)

Fig. 10

Window Slider Kit
Minimum:26.6"(67.5cm)
Maxmum:48.5"(123cm)

Fig. 11

Fig. 6

Take the hose out

Fig. 3

Fig. 4

Slide out

Fig. 8

Slide onto

Fig. 7

Fig. 5

Extend the side of hose

Vertical
window

Horizontal
window