Connect network devices, About connectors – Cisco SFS 7008 User Manual

Page 30

Advertising
background image

30

b. Enter the user name and password. The default user name is super, and the default password is

super.

c.

Enter the enable command.

d. Enter the configure command.

e.

Enter the interface mgmt-ethernet command.

f.

Enter the option dhcp command. The chosen method will be persistent across module reboots.

g. Enable the management port by entering the no shutdown command.

h. Save the configuration to preserve it between reboots.

If you have two Fabric Controllers installed in Core slots, you will receive a message asking if you
want to save the configuration to the Standby Controller.
i.

Answer Yes to save the configuration across both controllers.

Connect Network Devices

This section describes how to connect the InfiniBand system to other network devices. InfiniBand
devices can be connected to InfiniBand-enabled servers.

About Connectors

The Topspin 270 device supports the following types of connectors:

Management ports:

Serial console port: male DB-9 connector.

Ethernet Management port: RJ-45 jack for unshielded twisted-pair connections.

Switch card: 4X 10 Gbps InfiniBand connectors.

Login: super
Password: super
Topspin-270>

Topspin-270> enable
Topspin-270#

Topspin-270# configure
Topspin-270(config)#

Topspin-270(config)# interface mgmt-ethernet

Topspin-270(config-if-mgmt-ethernet)# option dhcp

Topspin-270(config-if-mgmt-ethernet)# no shutdown

Topspin-270(config-if-mgmt-ethernet)# exit
Topspin-270(config)# exit
Topspin-270# copy running-config startup-config

Advertising