Fabric Controller LEDs

Each Fabric Module has two sets of LED indicators.

The two LEDs (green or yellow) are the module status indicators (

Table 5-5

).

The single LED (green only) indicates whether of not the module is the active system master
(

Table 5-6

).

Location

Refer to

Figure 5-1

to view the front panel of the chassis.

Figure 5-4: Locate Fabric Controller LEDs

Interpreting the Fabric Controller LEDs

Module
Status

Active System Master Indicator

Table 5-5: Interpreting the Fabric Controller’s Module Status LEDs (see

Figure 5-1

and

Figure

5-4

)

Color

State

Indication

Green over
Yellow

off

No system power, or LED failure.

Green

solid on

System running with no errors detected.

Green

off

No power to the fabric controller, LED failure, or
yellow LED is On.

Yellow

off

No failure on the fabric controller.

Yellow

solid on

Module error detected. Operator intervention
required.

Yellow

blinking

Identify. Assists in identifying a particular Field
Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the
diag LED test. Refer to the Command Line
Reference Guide
for more information.

Table 5-6: Interpreting the Fabric Controller’s Master Status LED (see

Figure 5-4

)

Color

State

Indication

Active Master Status Indicator

Green

on

This module is currently the system master.
Note that only fabric modules in one of the two
core slots can become master.

Green

off

This module is not the active system master.
Note that only fabric modules in one of the two
core slots can become master.