Run card tests, Run a card self-test – Cisco SFS 7008 User Manual

Page 90

Advertising
background image

90

Run Card Tests

References to “Cards” refers to fabric controllers, management I/O modules, node cards and the chassis
ID module. Fans and power supplies are not included in the Card tests; they can be tested through the
standard chassis test (

page 93

), or as individual components.

The following tests are available to locate and diagnose one or more cards in the chassis:

LED

Self-test

page 90

Run a Card Self-Test

To perform a diagnostic self-test on a card:
1. Enter the diag card # command.

You cannot stop the card test once it has begun.

Example

2. Exit the test to view the progress of the test.

The test takes approximately 5 - 8 minutes.

Example of test in progress

Topspin-270> enable
Topspin-270# config
Topspin-270(config)# diag card 11
Topspin-270(config-diag-card-11)# test self-test
Topspin-270(config-diag-card-11)# start
Topspin-270(config-diag-card-11)# exit
Topspin-270(config)# exit

Topspin-270# show diagnostic card 11
================================================================================
Diagnostic Tests For Cards
================================================================================
test : self-test
slot-id : 11
iterations : 1
action : start
result : In progress
percentage-completed : 0
result-string :

Advertising