Monitor the system with the cli, Monitor the power supplies, Monitor the fans – Cisco SFS 7008 User Manual

Page 86

Advertising
background image

86

Figure 5-21: Element Manager Sensors Tab

6. Note the OperStatus field. A status of “up” indicates that the sensor is functioning properly.
7. Note the Temperature field. Each slot has an individual temperature sensor. The Alarm and

Shutdown temperatures vary by slot type.

Monitor the System With the CLI

For a complete list of CLI commands, refer to the CLI Reference Guide.
Use the following CLI commands to monitor the Power Supplies, the fans, and the sensors:

Monitor the Power Supplies

show power-supply

Example

Monitor the Fans

show fan

An oper-status of “up” means that the blower is operating correctly within the fan unit.

Topspin-270> show power-supply

================================================================================
Power-supply Information
================================================================================
ps type oper-status utilization voltage
--------------------------------------------------------------------------------
1 AC up n/a 48
2 AC down n/a 48

================================================================================
Power-supply Seeprom
================================================================================
product pca pca fru
ps serial-number serial-number number number
--------------------------------------------------------------------------------
1 - - - -
2

Advertising