Chromalox

®

DIVISION

4

SECTION

GCH-GCHIS

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation, Operation

and

RENEWAL PARTS IDENTIFICATION

PE419-5

161-027331-001

FEBRUARY, 2009

(Supersedes PE419-4)

GENERAL

© 2010 Chromalox, Inc.

GCH and GCHIS-6 Circulation Heaters

For Steam, Gas and Air Heating

Read and understand all instructions before
installing, servicing or operating product. Failure
to do so could result in personal injury or property
damage.

The GCH and GCHIS-6 series is a general-purpose gas or steam

circulation heater intended for use indoors.

The 6 INCOLOY® sheathed tubular elements are centered in a 5”

diameter heating chamber and welded to a removable flange. The
assembly is surrounded by 1-1/2” insulation and sheet metal jacket.
The GCH series has a steel flange and chamber. The GCHIS series has
stainless steel flange and chamber.

Depending upon the order specifications, the GCH-GCHIS-6 may

or may not be factory equipped with an AR or other Chromalox ther-
mostat. Such thermostats function to control outlet temperatures and to
limit internal temperatures under abnormal flow conditions. These
controls do not fail safe.

The system designer is responsible for the safety
of this equipment and should install adequate
back-up controls and safety devices with their
electric heating equipment. Where the conse-
quences of failure could result in personal injury or
property damage, back-up controls are essential.

Specifications — Table A

Dimensions (In.)

Model Volts Phase

kW

W/In

2

A

B

C

D

GCH-60905

240 or 480

1 or 3

9

23.8

41-3/4

30

25

11-3/8

GCH-61205

240 or 480

1 or 3

12

23.1

48-3/4

37

25

14-7/8

GCH-62005

240 or 480

1 or 3

20

23.3

60-1/4

48-1/2

25

20-5/8

GCH-62505

240 or 480

3Y

25

22.9

73-5/8

61-7/8

25

27-5/16

GCH-63005

240 or 480

3Y

30

22.7

86-5/8

74-7/8

25

33-7/8

GCHIS-6045

240 or 480

3Y

4

15

41-3/4

30

25

11-3/8

GCHIS-6085

240 or 480

3Y

8

15

48-3/4

37

25

14-7/8

GCHIS-6125

240 or 480

3Y

12

15

60-1/4

48-1/2

25

20-5/8

GCHIS-6155

240 or 480

3Y

15

15

73-5/8

61-7/8

25

27-5/16

GCHIS-6205

240 or 480

3Y

30

15

86-5/8

74-7/8

25

33-7/8

A

B

12-1/32”

C

8-3/4”

1-1/4”

8”

Mtg. Lugs

3/8-16 Tap

1-1/2” Deep

1-3/8” K.O.

For 1” Conduit

1” Pipe

Inlet

1” Pipe

Outlet

AR

Thermostat

Advertising