Lcd status messages update – Dell POWEREDGE 2950 User Manual

Page 15

Advertising
background image

Information Update

15

LCD Status Messages Update

Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 2950 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.

Table 1-2.

LCD Status Messages

Code

Text

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character string that
can be defined by the user
in the System Setup
program.

The SYSTEM NAME
displays under the
following conditions:

• The system

is powered on.

• The power is off

and active errors
are displayed.

This message is for
information only.

You can change
the system ID and
name in the System
Setup program.
See “Using the System
Setup Program” in the
Hardware Owner’s
Manual.

E1000

FAILSAFE,

Call Support

Check the system event
log for critical failure
events.

See “Getting Help” in
the Hardware Owner’s
Manual.

E1118

CPU Temp

Interface

The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.

Turn off power to the
system and restart the
system. If the problem
persists, see “Getting
Help” in the Hardware
Owner’s Manual.

Advertising