The Ring Statistics Screen

HSIM-F6 User’s Guide

3-11

3.6.1

HSIM-F6 FDDI Ring Statistics Screen Fields

The HSIM-F6 FDDI Ring Statistics screen allows the user to monitor the
current HSIM-F6 operational status.

The following list describes the Ring Statistics screen fields:

RING STATE

Displays the current ring state. The possible ring states are as follows:

Ring-Op -

The ring is functioning correctly.

Isolated -

The HSIM-F6 is not attached to the ring.

Non-Op -

The HSIM-F6 is attempting to enter the ring.

Detect -

The claim (beacon) process of the FDDI ring
protocol has exceeded one second. There may be a
problem.

Non-Op-Dup -

The ring failed to complete the claim (beacon)
process. This usually indicates a duplicate FDDI
address.

Ring-Op-Dup -

The ring is operational, but a duplicate FDDI
address may be present somewhere on the network.

Directed -

The claim (beacon) process did not complete
within ten seconds. The HSIM-F6 is sending
directed beacons to indicate a problem.

Trace -

A problem has been detected with the HSIM-F6 or
the nearest active upstream neighbor (NAUN). A
trace is being sent to notify the nearest active
upstream neighbor of the problem.

RING-OP COUNT

The Ring-Op Count keeps track of the number of times the FDDI ring has
initialized since the last time the HSIM-F6 (or host device in which it
resides) was reset. If this number grows steadily over a brief period of
time, it signifies the ring is unstable.