Viewing drive assignments, Viewing array – Contec SPI-8451-LVA User Manual

Page 56

Advertising
background image

6. RAID Controller

SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA

49

Viewing Drive Assignments

The View Drive Assignments <2> option in the Main Menu displays whether drives are assigned to a
disk arrays or are unassigned.

Under the “Assignment” column, drives are labeled with their assigned disk array or shown as “Free” if
unassigned. Such “Free” drives can be used for a future array or used as a spare drive when a drive fails
in a mirrored array. Unassigned drives are not accessible by the OS. The menu also displays the data
transfer mode that relates to speed used by each drive (U5 refers to 100MB/sec transfers, U4 refers to
66MB/sec transfer, etc…)

FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.

[ View Drive Assignments ]

Channel:ID Drive Model Capacity(MB) Assignment Mode

1 : Mas QUANTUMCR8.4A 8063

Array 1 U5

1 : Sla QUANTUMCR8.4A 8063 Free U5
2 : Mas QUANTUMCR8.4A 8063

Array 1 U5

[ Keys Available ]

[

↑] Up [↓] Down [ESC] Exit Mode (U=UDMA, P=PIO, D=DMA)

Viewing Array

The Define Array <3> option in the Main Menu displays the define array.

FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.

[Define Array Menu]

Array No RAID Mode Total Drv Capacity(MB) Status
Array 1 Stripe 2 16126
Functional
Array 2 —— —— — ——
Array 3 —— —— —— ——
Array 4 —— —— —— ——

[ Keys Available ]

Note: * — Bootable Array

[

↑] Up [↓] Down [ESC] Exit [Enter] Select [Space] Change Boot Drive

Advertising