A axis no. p command id / data delimiter – Canon GALVANO GC-251 User Manual

Page 18

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

18

Parameter of controller can be changed by the following sending method to controller.
Also in response to parameter send, the controller always returns a reply with data.

The data contents depend on the command. (For details, see 7-2, “Command Details.”)
When changed a parameter of it, to start it by the same setting in power supply on at the next
time; the parameter that changed, it is necessary to write in it at ROM.

Parameter send

A Axis

No. P Command ID / Data Delimiter

E.g. LQ gain parameter ID = 6 Data = 4500

A1P006 / 4500 (LF)

(ASCII code: 0x41 0x31 0x50 0x30 0x30 0x36 0x2f 0x34 0x35 0x30 0x30 0x0a)

A 1 P 0 0 6 / 4 5 0 0 (LF)

Parameter reply

A Axis

No. P Command ID / Data Delimiter

E.g. LQ gain parameter ID = 6 Data = 4500

A1P006 / 4500 (LF)

(ASCII code: 0x41 0x31 0x50 0x30 0x30 0x36 0x2f 0x30 0x0a)

A 1 P 0 0 6 / 0 (LF)

Axis No.

1 or 2

Command ID
Decimal, 3-digit
(See 7-1 for details)

Parameter setting

Decimal

Parameter

Delimiter

LF or CR

Axis No.

1 or 2

Command ID
Decimal, 3-digit
(See 7-1 for details)

Parameter setting

successful / unsuccessful

0 or 1

Parameter

Delimiter

LF or CR

Advertising