(Target Position Data)

XDAT

YDAT

The data length of the target position data by the high-speed serial communication can be
changed by two following parameters.

The target position data length can be changed in 16bit – 20bit.

Parameter ID

DATA

16

16bit Data

17

17bit Data

18

18bit Data

19

19bit Data

20

20bit Data

The least significant bit position of the target position data of high-speed serial communication
20bit data can be set by following parameter.
The right shifts this number of bit make the target position data.

Parameter ID

DATA

0

0bit position

1

1bit position

2

2bit position

3

3bit position

4

4bit position


An example of the setting as follows.

Parameter ID = 67 16

Parameter ID = 68 1

Parameter ID = 67 18

Parameter ID = 68 2