Canon GALVANO GC-251 User Manual

Page 24

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

24

Status

STS

The status of controller is sent by status line (STS) of high-speed serial communication.
The contents of status sending from a controller can be changed by the following parameter.

Parameter ID

Data

1

Controller Condition

2

Current position (Axis 1)

3

Current position(Axis 2)

4

Current position(Axis1 , Axis2)

Each status contents are as follows.

1:

Controller Condition

Output the status of the controller.

READY

Servo ON and ready to control by high-speed serial communication.

ALARM1 :

Alarm output (priority high)

(See 5-3 Digital Input-Output Function. Same meaning as ‘Axis 1 Error 1

(priority high)’ , ‘ Axis 2 Error 1(priority high)’ )

ALARM2 :

Alarm output (priority low)

(See 5-3 Digital Input-Output Function. Same meaning as ‘Axis 1 Error 2

(priority low)’ , ‘ Axis 2 Error 2(priority low)’ )