INPOS

In-position signal

(When current position moves into the in-position width, this signal will

be output.)

2:

Current position (Axis 1)

Output the Axis 1 encoder position.

Position Data length: 20bit.

3:

Current position (Axis 2)

Output the Axis 2 encoder position.

Position Data length: 20bit.

4:

Current position (Axis1, Axis2)

The encoder position of the Axis 1 and the Axis 2 is alternately output.

Position Data length: 21bit.

The first 1bit shows the axis (Axis Flag).

Axis Flag = 0 Axis 1

Axis Flag = 1

Axis 2

Note: After the position of the encoder is actually detected, the encoder position status is

output after a delay of 2 servo sampling. (1 servo sampling = 10μsec)

Note: Only when controlling by high-speed serial communications, the status output is output.

It is not output when operating with the internal clock (raster scan and movement in the step).