4.4.

Position Command Input by High-speed Serial Communication

For a vector scan, give target position data to the controller by high-speed serial communication, The

data is updated as required.

Switch the controller to the status of receiving target position data by high-speed serial communication.

For switching, it is necessary to enter high-speed serial communication signals into the controller in

advance.

GALILEO

Select an axis for high-speed serial communication.

Switch HiSpeed Serial to Start.

This switching makes the controller follow target position data by high-speed serial communication.

Switch HiSpeed Serial to OFF.

Input of the MOVE command is awaited.

RS-232C commands

Switch to high-speed serial communication (Command ID = 23 Data = 7)

Return to internal clock operation (Command ID = 23 Data = 0)