CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

40

The signal name is displayed on the evaluation monitor board. Please check the signal after referring

to the table of the following pin arrangement.

Analog monitor output connector

Connector model number

Connector Model

No.

Manufacturer

Board side

XG4C-1034

OMRON

Cable side

XG4M-1030-T

OMRON

Connector pin arrangement

Pin No.

Monitor Board

Signal Name

Signal Description

1

A1

Axis 1 current command value

2

A2

Axis 1 analog monitor 1 (Monitor item switching)

3

A3

Axis 1 analog monitor 2 (Monitor item switching)

4

A4

Axis 1 analog monitor 3 (Monitor item switching)

5

A5

Axis 2 current command value

6

A6

Axis 2 analog monitor 1 (Monitor item switching)

7

A7

Axis 2 analog monitor 2 (Monitor item switching)

8

A8

Axis 2 analog monitor 3 (Monitor item switching)

9 A9

Analog

GND

10 A10

Analog

GND

The controller has three monitor terminals for each of the two axes to check the operation status.

The output signal contents can be changed and the output magnification can also be changed.

(For details, see 5.2, “Analog Monitor Output Switching.”)