Canon GALVANO GC-251 User Manual

Page 42

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

42

5.2. Analog

Monitor

Output Selecting

The analog monitor output can be switched to monitor various operation and signal statuses.

This switching can be executed from [GALILEO] or [RS-232C command send].

Output contents

Terminal

Power-on

Selection

Signal Description

Signal Level (At Power-on)

A2 (Axis 1)
A6 (Axis 2)

Phase A of Encoder Head 1

Phase A of Encoder Head 2

Phase A of encoder after synthesis

*

Positional deviation signal

1.46 mV / pulse

A3 (Axis 1)
A7 (Axis 2)

Position

0.091 mV / pulse

*

Velocity

0.091 mV / pulse / 10 usec

Coarse

angle

Fine

angle

A4 (Axis 1)
A8 (Axis 2)

Phase B of Encoder Head 1

Phase B of Encoder Head 2

Phase B of encoder after synthesis

*

Target position

0.091 mV / pulse

The signal level differs between signals. The output magnification can be switched individually.