Canon GALVANO GC-251 User Manual

Page 45

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

45

5.3.

Digital Input-Output Function

The controller has a digital input-output function for checking the status of the controller.

Pin

No.

I/O Signal

Description Logic

Explanation

A1

Output

Axis 1 Error 1 (Priority high)

1:

Error

If an error occurs, the
corresponding error signal is
output.
According to the priority of the

error, Error 1 or 2 is output.

See 9-2, “Errors.”

B1

Output

Axis 1 Error 2 (Priority low)

1: Error

B2

Output

Axis 2 Error 1 (Priority high)

1: Error

A3

Output

Axis 2 Error 2 (Priority low)

1: Error

A2

Output

Axis 1 servo interrupt period

Edge

These are output at a servo
interrupt timing in the
controller.

B3

Output

Axis 2 servo interrupt period

Edge

In addition, the following, digital I/O is prepared as an operation setting of the controller.

Pin

NO.

I/O Signal

Description

Logic

Explanation

A5

Input External Sampling Signal

INT

generation

When external signal is used for

servo sampling clock.

(Do not use it usually.)

B5 Input

External

Trigger

Signal

High ON

See 6-2, “Operation that

synchronizes with external

trigger Signal input(raster scan)

A6

Input Activation mode switching

See 6-1, “Setting Controller

Activation Mode”

Advertising