Canon GALVANO GC-251 User Manual

Page 49

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

49

Input the external trigger signal

The external trigger signal is input from the digital I/O connector.

See 5-1 ‘Connector Pin Arrangement

Connector pin arrangement

Pin

NO.

Monitor Board

Signal Name

I/O Signal

Description Logic Remarks

B5

10 Input

External

Trigger

Signal High ON

See Circuit below.

Connection Specifications

3.3V TTL Input

Operation procedure

(Raster Scan Parameter Settings)

Set Parameter ID =26

Raster Scan Time

Set Parameter ID =27

Raster Scan Duty Ratio

Set Parameter ID =28

Raster Scan Angle

(Raster Scan Operation

Send Command ID=8 Data=6 Movement Start (Movement to the Initial position

of raster scan)

Send Command ID=23 Data=8 (One way scan)

Data=9 (One coming and going)

(Reference: Data =3 in case of continuous operation)

Input the external trigger Signal

Send Command ID=23 Data=0 Scan Stop

Notes

The external trigger input during raster scan move is ignored.

10usec or less is uneven from the external trigger signal input at time until beginning to

actually operate.

FPGA

3.3V-TTL

R

100

Connector

Select either

Advertising