8.2. Parameter

Details

Parameter ID

0

Parameter

Name

CW Limit

Data

Movable range (Unit: pulse)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

Specify the limit of the clockwise movable range viewed from the axial direction of the
motor.
In case of input or movement beyond the movable range of angle, an error is output.

Note: The relationship between the number of pulses and the angle depends on the motor.

Related
Command
/Parameter

Parameter ID

1

Parameter

Name

CCW Limit

Data

Movable range (Unit: pulse)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

Specify the limit of the counterclockwise movable range viewed from the axial direction
of the motor.
In case of input or movement beyond the movable range of angle, an error is output.

Note: The relationship between the number of pulses and the angle depends on the motor.

Related
Command
/Parameter

Parameter ID

2

Parameter

Name

Max Velocity

Data

Maximum velocity (Unit: pulse/s)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to specify step movement by command execution.
This maximum velocity applies if “Command ID = 22: Target Velocity Setting” is not set.

Note: The relationship between the number of pulses and the angle depends on the motor.

Related