Canon GALVANO GC-251 User Manual

Page 71

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

71

Parameter ID

15

Parameter

Name

High-speed Serial Communication
Offset

Data

High-speed Serial Communication Offset (Unit: pulse)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

Set this parameter, when a center position of the high-speed serial communications
data is offset.
This is effective, when operating by high-speed serial communications.
0 is set usually.
E.g. Data = 100
High-speed serial communication data(16bit) 0x8000 = 100 encoder pulse position.

Related
Command
/Parameter

Parameter ID

16

Parameter

Name

First Digital Notch Filter Central
Frequency

Data

Central frequency of the first digital notch filter (Unit: Hz)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the central frequency of the first digital notch filter.

Related
Command
/Parameter

First Digital Notch Filter Q Value (Parameter ID = 17)
First Digital Notch Filter Depth (Parameter ID = 18)

Parameter ID

17

Parameter

Name

First Digital Notch Filter Q Value

Data

Q value of the first digital notch filter (Unit: ×100)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the Q value of the first digital notch filter.
Set a value multiplied by 100.

Related
Command
/Parameter

First Digital Notch Filter Central Frequency (Parameter ID = 16)
First Digital Notch Filter Depth (Parameter ID = 18)