Parameter ID

18

Parameter

Name

First Digital Notch Filter Depth

Data

Depth of the first digital notch filter (Unit: dB)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the depth of the first digital notch filter.

Related
Command
/Parameter

First Digital Notch Filter Central Frequency (Parameter ID = 16)
First Digital Notch Filter Q Value (Parameter ID = 17)

Parameter ID

19

Parameter

Name

Second Digital Notch Filter Central
Frequency

Data

Central frequency of the second digital notch filter (Unit: Hz)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the central frequency of the second digital notch filter.

Related
Command
/Parameter

Second Digital Notch Filter Q Value (Parameter ID = 17)
Second Digital Notch Filter Depth (Parameter ID = 18)

Parameter ID

20

Parameter

Name

Second Digital Notch Filter
Q Value

Data

Second digital notch filter Q value (Unit: ×100)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the Q value of the second digital notch filter.
Set a value multiplied by 100.

Related
Command
/Parameter

Second Digital Notch Filter Central Frequency (Parameter ID = 16)
Second Digital Notch Filter Depth (Parameter ID = 18)

Parameter ID

21

Parameter

Name

Second Digital Notch Filter Depth

Data

Depth of the second digital notch filter (Unit: dB)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the depth of the second digital notch filter.

Related
Command
/Parameter

Second Digital Notch Filter Central Frequency (Parameter ID = 16)
Second Digital Notch Filter Q Value (Parameter ID = 17)