Canon GALVANO GC-251 User Manual

Page 73

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

73

Parameter ID

22

Parameter

Name

Digital Low-pass Filter Cutoff
Frequency

Data

Cutoff frequency of the digital low-pass filter (Unit: Hz)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the cutoff frequency of the digital low-pass filter.

Related
Command
/Parameter

Parameter ID

23

Parameter

Name

First Analog Notch Filter Central
Frequency

Data

Central frequency of the first analog notch filter (Unit: Hz)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the central frequency of the first analog notch filter.
The setting range is from 9750 to 42820 Hz.

Related
Command
/Parameter

Parameter ID

24

Parameter

Name

Second Analog Notch Filter Central
Frequency

Data

Central frequency of the second analog notch filter (Unit: Hz)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the central frequency of the second analog notch filter.
The setting range is from 9750 to 42820 Hz.

Related
Command
/Parameter

Parameter ID

25

Parameter

Name

Third Analog Notch Filter Central
Frequency

Data

Central frequency of the third analog notch filter (Unit: Hz)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the central frequency of the third analog notch filter.
The setting range is from 9750 to 42820 Hz.

Related
Command
/Parameter

Advertising