Canon GALVANO GC-251 User Manual

Page 76

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

76

Parameter ID

31

Parameter

Name

Raster Scan Start Position

Data

Raster scan start position (Unit: 0 or 1)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the start of raster scan (operation by command) from the
negative or positive side.
0: Scan start from the negative side
1: Scan start from the positive side

Related
Command
/Parameter

Raster Scan Time (Parameter ID = 26)
Raster Scan Duty Ratio (Parameter ID = 27)
Raster Scan Angle (Parameter ID = 28)
Raster Scan Interval Time (Parameter ID = 30)

Parameter ID

32

Parameter

Name

Z-phase Offset

Data

Z-phase (0-point position) offset value (Unit: pulse)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set an offset from the actual Z-phase position for determining
the 0-pulse position.

Related
Command
/Parameter

Parameter ID

33

Parameter

Name

Acceleration Time

Data

Acceleration time (Unit: ms)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is valid when “Command ID = 18: Acceleration Control” is ON.
Set the time until the velocity reaches the value set by “Parameter ID = 2: Max Velocity”
in step movement (movement by command).
If 0 is set, the target command of the maximum velocity is followed from the start of
movement.

Related
Command
/Parameter

Acceleration control (Command ID = 18)
Maximum velocity (Parameter ID = 2)
Movement start (Command ID = 8)