Canon GALVANO GC-251 User Manual

Page 77

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

77

Parameter ID

34

Parameter

Name

Deceleration Time

Data

Deceleration time (Unit: ms)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the deceleration time for a stop by “Command ID = 9:
Forced Stop.”

Related
Command
/Parameter

Forced Stop (Command ID = 9)

Parameter ID

36

Parameter

Name

Out-position width

Data

Out-position (Unit: pulse)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

An error is output if a difference from the target value exceeds the setting of this
parameter becoming static.
Setting 0 is invalid.

Related
Command
/Parameter

Bit 13 “Current Saturation” becomes 1 in error read (Command ID = 15).

Parameter ID

40

Parameter

Name

Feed-forward Gain

Data

Feed-forward gain (Unit: none)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the feed-forward gain. This is usually set at shipping.
Setting 0 disables feed-forward.

Related
Command
/Parameter

Parameter ID

42

Parameter

Name

Overshoot Control

Data

Overshoot Control (Unit: none)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set pole rearrangement. This is usually set at shipping.
Setting 100 disables pole rearrangement.

Related
Command
/Parameter