Quick service guide, Uick service guide, Maintenance 4.2. quick service guide – CMA Dishmachines L-1X16 User Manual

Page 12

Advertising
background image

Maintenance

4.2.

Quick service guide

MODEL L-1X & L-1X16 PARTS MANUAL Rev. 1.14

Page

11

MODELS: L-1X, L-1X16 UNDER COUNTER

TECHNICAL ISSUE

CAUSE

SOLUTION

Delimer switch in delime position

Flip to

NORMAL

position

Wash Pump motor will not shut off

Faulty delimer switch

Replace switch, P/N 00475.30

Faulty manual drain switch

Replace switch, P/N 03406.62

Faulty contactor

Replace contactor, P/N 00404.82

Continues cycles

Faulty #1 micro switch (start/stop)

Replace switch, P/N 00411.00

Faulty start/fill switch

Replace switch, P/N 03470.01

Faulty #1 micro switch

Replace switch, P/N 00411.00

Low water level inside machine

Add water to tank to activate float switch, adjust
water cam on timer

Sustainer heater not working

Faulty float switch

Replace switch, P/N 13463.10

Machine not level

Level machine

Faulty ice cube relay

Replace relay, P/N 00631.00

Machine does not drain

Faulty #3 micro switch (drain)

Replace switch, P/N 00411.00

Faulty drain valve

Replace drain valve, P/N 04103.00

Does not hold water

Faulty #3 micro switch (drain)

Replace switch, P/N 00411.00

Clogged or defective drain valve

Clean and/ or replace drain valve, P/N 04103.00

Tank overflows overnight

Debris in water Solenoid Valve

Clean and replace valve diaphragm, P/N
00707.00

Water leaks out of Vacuum Breaker

Dirty or defective vacuum breaker kit
assy

Clean or replace internal parts, P/N 03623.00

Faulty check valve

Replace check valve, P/N 00715.00

Male/ female plug on the back of control
drawer is loose

Secure plug

Wash Pump motor not running

Faulty door reed switch

Replace reed switch, P/N 00557.55

Faulty 7th micro switch

Replace switch, P/N 00411.00

Faulty motor contactor

Replace contactor, P/N 00404.82

Faulty Start/Fill Switch

Replace switch, P/N 03470.01

Timer does not rotate

Faulty #1 micro switch

Replace switch, P/N 00411.00

Faulty timer motor

Replace motor assembly, P/N 00501.00

Faulty #4 Micro switch

Replace switch, P/N 00411.00

Machine does not fill

Debris inside water solenoid valve or

Faulty valve

Clean and replace valve diaphragm, P/N

00707.00

Faulty water solenoid coil

Replace solenoid coil, P/N 00738.10

Delimer switch in wrong position

Switch to

NORMAL

position

Sanitizer pump does not run

Faulty 5th micro switch

Replace switch, P/N 00411.00

Faulty sanitizer pump motor

Replace motor, P/N 00416.00

Advertising
This manual is related to the following products: