4.3. Troubleshooting

PROBLEM LIKELY

CAUSE

SOLUTION

Power off at circuit breaker

Reset circuit breaker

Defective power switch

Replace power switch

P/N: 00433.10

Machine inoperative

Defective timer assembly motor

Replace timer assembly motor

P/N: 00501.00

Door is open

Close door

Control drawer is pulled out

Secure control drawer

Defective reed (door) switch

Replace reed (door) switch

P/N: 00557.55

Defective timer assembly
(Cam 7)

Replace timer assembly*

P/N: 00408.80

Defective pump motor contactor

Replace contactor

P/N: 00404.82

Pump Motor inoperative

Defective pump motor

Replace pump motor

P/N: 00201.00

Defective reed (door) switch

Replace reed (door) switch

P/N: 00557.55

Defective pump motor contactor

Replace contactor

P/N: 00404.82

Pump Motor runs with door
open

Delime switch is on

Turn off delime switch

Motor runs continuously

Delime switch is on

Turn off delime switch

Defective thermostat on heater

Replace heater

P/N: 04109.10

Defective heater relay

Replace heater relay

P/N: 00631.00

Defective timer assembly
(Cam 8)

Replace timer assembly *

P/N: 00408.80

Defective heater

Replace heater

P/N: 04109.10

Defective float switch

Replace float switch

P/N: 13463.00

Fill wash tank completely

Optional Sustainer Heater
(no heat)

Float switch not actuated

Level machine

Defective thermostat on heater

Replace heater

P/N: 04109.10

Defective timer assembly
(Cam 8)

Replace timer assembly *

P/N: 00408.80

Optional Sustainer Heater
(never turns off)

Defective heater relay

Replace heater relay

P/N: 00631.00

*The timer assembly motor (

P/N: 00501.00

) or micro switches (

P/N: 00411.00

) can be replaced

independently if that is the only component that has failed.