L-1x and l-1x16 operational cycle, L-1x, L-1x16 o – CMA Dishmachines L-1X16 User Manual

Page 4: Perational, Ycle

Advertising
background image

1.2.

L-1X and L-1X16 Operational Cycle

The L-1X and L-1X16 Operational Cycle has a total cycle time of 2 minutes (120
seconds). The Timing Diagram and the steps listed below detail the individual functions
that are executed during each Operational Cycle.

Seconds:

0 10 20 30 40 50 60 70

80 90 100

110

120

WASH

RINSE

DRAIN

Instant

Start Relay

Cam 1

Start/Stop

Cam 2

Detergent

Drain/Rack

Counter

Cam 3

Cam 4

Flush/Fill

Cam 5

Sanitizer

Cam 6

Rinse

Pump Motor

Cam 7

Heater*

Cam 8

*

Heater is optional

1. With the machine powered up, toggling the START switch begins a cycle.

a) Toggling the START switch energizes both the cam timer motor and the instant

start relay. The instant start relay latches ON the power to the cam timer motor so
that the START switch can be released a moment after it has been toggled without
the cam timer motor losing power.

b) After about 2 seconds, Cam 1—the Start cam—latches ON the power to the cam

timer motor and drops out the instant start relay. The cam timer motor continues
to run for a total of 2 minutes, at which time it switches OFF—resetting the cam
timer—and waits for the next start command.

2. Cam switch 7 controls the pump motor. The pump motor comes ON at the beginning

of the operational cycle and continues to run until the end of the drain function
(controlled by cam switch 3), at which time it turns off for about eight seconds

MODEL L-1X & L-1X16 INSTALLATION & OPERATION MANUAL Rev. 1.14