Installing the pump, Nstalling the – Conair PD3 User Manual

Page 7

Advertising
background image

4

Set or mount the vacuum pump in any convenient location.

Refer to the accompanying wiring diagram for connection of
the main power supply and the conveying control circuit.You
must provide a wall-mounted disconnect for three-phase elec-
trical connection. Incoming voltage and current must match
the electrical specifications on the pump data plate and serial
tag. Check for proper rotation of the pump after power has
been connected and before operation.

Install vacuum lines to loader stations and the dust collector.
Connect the dust collector vacuum outlet to the pump inlet.

INSTALLATION AND OPERATION NOTE:
The pump inlet is equipped with a vacuum relief
valve to prevent the vacuum from exceeding 12 in.
Hg. Excessive vacuum will reduce the life of the
pump and can destroy it.

For special applications requiring a higher vacuum
level, consult Conair service. If the vacuum relief
valve is adjusted by any person other than a facto-
ry service representative, the warranty is voided.

I

NSTALLING

THE

P

UMP

IMB036/0898 Positive Displacement Pump

Positive

Displacement

Vacuum Pump

Central

Vacuum Line

Material

Inlet

Material

Receivers

Receiving

Hoppers

Central Dust Collector

Advertising
This manual is related to the following products:

7.5, 5, 10