3 power distribution panel, 4 fan unit, 3 power distribution panel – Cisco ONS 15200 User Manual

Page 30: 4 fan unit, Figure 3-3, Table 3-1, Fan unit” section on, Show

Advertising
background image

3-4

Cisco ONS 15200 Product Description

78-13766-01

Chapter 3 Product Hardware

Modularity and Ancillary Equipment

Figure 3-3

A functional view of the ONS 15201 SCU

3.1.3 Power Distribution Panel

ONS 15200 site configurations can include a power distribution panel (PDP). The PDP distributes power
to the ONS 15200 site and provides power redundancy. It uses input and output fusing to provide system
protection.

3.1.4 Fan Unit

All Release 1.0.1 (or later) ONS 15252 MCU site configurations require a fan unit mounted above the
ONS 15252 MCU in the equipment rack; Release 1.0 shelves do not use the fan unit. The fan unit
contains eight small fans that run simultaneously at constant speed. The fans push air down through the
MCU to cool the CLIP modules. The fan unit is powered by its own dual -48 VDC power inlets
independently of the MCU. If the fan unit fails, it generates an alarm to indicate multi- or single-fan
failure. Located on the front panel of the fan unit are three LEDs to indicate alarm status.

Table 3-1

lists

the LED status and cause of alarm.

A

CFM

OUT
IN

IN

OUT

A-SIDE

OPTICAL

B-SIDE
OPTICAL

LEGEND
A - A side
B - B side
CFM - Collector Filter Module
DWDM - dense wavelength division multiplexing

TO AND FROM

THE DWDM LAYER

TO AND FROM
THE DWDM LAYER

54636

Tx

B

TO AND FROM THE CLIENT LAYER

(EXTERNAL TO THE ONS 15200 SYSTEM)

CLIP

Table 3-1

Fan Unit LED Status

LED

Status

Cause

Red

Major alarm

Multi-fan failure

Yellow

Minor alarm

Single-fan failure and/or single
48 VDC failure

Green

Normal

Power on

Advertising