Integrated storage controller card, Removing the integrated storage controller card, 2 open the system. see "opening the system – Dell POWEREDGE R610 User Manual

Page 111: Removing the integrated storage, Controller card, Integrated storage

Advertising
background image

Installing System Components

111

8 If not already done, connect the power cable to DVD_PWR and the

interface cable to SATA_A on the system board. See Figure 6-1.

9 Replace the front bezel, if applicable. See "Removing and Replacing the

Optional Front Bezel."

10 Reconnect the system and peripherals to their electrical outlets.

Integrated Storage Controller Card

Your system includes a dedicated expansion-card slot on riser 1 for an

integrated SAS or PERC controller card that provides the integrated storage

subsystem for your system’s internal hard drives. The controller supports SAS

and SATA hard drives and also enables you to set up the hard drives in RAID

configurations as supported by the version of the storage controller included

with your system.

Removing the Integrated Storage Controller Card

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

1 Turn off the system, including any attached peripherals, and disconnect

the system from the electrical outlet.

2 Open the system. See "Opening the System."
3 Disconnect the data cables from the controller card. See Figure 3-17.

To remove a connector, press the latches on both ends of the connector.

4 If you are removing a battery-cached PERC controller, disconnect the

RAID battery cable from the card.

CAUTION:

Disconnecting the RAID battery cable from a PERC card can cause

data loss if the "dirty cache" LED on the card is lit. The LED indicates that data is
still cached in controller memory and the data was not cleared at system
shutdown.

5 Remove the card from the storage controller card slot: