Dell POWEREDGE R610 User Manual

Page 24

Advertising
background image

24

About Your System

To resolve the problem and remove the LCD message, refer to the corrective

actions in the following table.

NOTE:

The following LCD status messages are displayed in the Simple format. See

“Setup Menu“to select the format in which the messages are displayed.

Table 1-1. LCD Status Messages

Code

Text

Cause

Corrective Actions

E1000

Failsafe

voltage

error.

Contact

support.

Check the system event log

for critical failure events.

Remove AC power to the

system for 10 seconds or

clear the SEL.
If the problem persists,

see "Getting Help."

E1114

Ambient Temp

exceeds

allowed

range.

Ambient temperature has a

reached a point outside of

the allowed range.

See "Troubleshooting

System Cooling

Problems."

E1116

Memory

disabled,

temp above

range. Power

cycle AC.

Memory has exceeded

allowable temperature and

has been disabled to

prevent damage to the

components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling

Problems."
If the problem persists,

see "Getting Help."

E1210

Motherboard

battery

failure.

Check

battery.

CMOS battery is missing or

the voltage is outside of the

allowable range.

See "Troubleshooting the

System Battery."

E1211

RAID

Controller

battery

failure.

Check

battery.

RAID battery is either

missing, bad, or unable to

recharge due to thermal

issues.

Reseat the RAID battery

connector. See "Installing

a RAID Battery" and

"Troubleshooting System

Cooling Problems."

Advertising