Dell POWEREDGE R610 User Manual

Page 32

Advertising
background image

32

About Your System

E1A15

SAS cable B

failure.

Check

connection.

SAS cable B is missing or

bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help."

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control

panel is missing or bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help."

E2010

Memory not

detected.

Inspect

DIMMs.

No memory was detected in

the system.

Install memory or reseat

the memory modules. See

"System Memory" or

"Troubleshooting System

Memory."

E2011

Memory

configuration

failure.

Check DIMMs.

Memory detected, but is

not configurable. Error

detected during memory

configuration.

See "Troubleshooting

System Memory."

E2012

Memory

configured

but unusable.

Check DIMMs.

Memory configured, but is

unusable.

See "Troubleshooting

System Memory."

E2013

BIOS unable

to shadow

memory. Check

DIMMs.

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

System Memory."

E2014

CMOS RAM

failure.

Power cycle

AC.

CMOS failure. CMOS

RAM not functioning

properly.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

Table 1-1. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions

Advertising