Dell POWEREDGE R610 User Manual

Page 49

Advertising
background image

About Your System

49

The following

DIMMs should

match

in

geometry:

x

,

x

,

...

Invalid memory

configuration. The specified

DIMMs do not match in size,

number of ranks, or number

of data lanes.

Ensure that the memory

modules are installed in a

valid configuration. See

"System Memory."

The following

DIMMs should

match

in rank

count:

x

,

x

,

...

The following

DIMMs should

match in size:

x

,

x

,

...

The following

DIMMs should

match

in size

and geometry:

x

,

x

,

...

The following

DIMMs should

match

in size

and rank count:

x

,

x

,

...

Thermal sensor

not detected on x

Invalid memory

configuration. A mismatched

DIMM is installed.

Ensure that the memory

modules are installed in a

valid configuration. See

"System Memory."

Time-of-day

clock stopped

Faulty battery or faulty chip. See "Troubleshooting the

System Battery."

Time-of-day not

set - please run

SETUP program

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager." If the

problem persists, replace the

system battery. See "System

Battery."

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

Advertising