Cooper Bussmann BRICK 6125TD User Manual

Brick, Fuses, 6125td series, time delay

Advertising
background image

Description

• Time Delay surface mount fuse capable of replacing

glass tube fuses in certain applications

• Environmentally rugged, complies with EIA-IS-722

Standard

• Solder Immersion Compatible
• Targeted for Consumer Electronics

Agency Information

• UL Recognition Guide & File numbers: JDYX2 & E19180.

• CSA Component Acceptance: 053787 C 000 & Class

No: 1422 30.

Environmental Data

• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:

ANSI J-STD-002, Test D

• Mechanical Shock: MIL-STD-202, Method 213B, Test

Condition A

• High Frequency Vibration: MIL-STD-202, Method 204D,

Test Condition D

• Resistance to Solvents: MIL-STD-202, Method 215A

Ordering

• Specify product code and packaging code

Soldering Method

• Wave Immersion: 260°C, 3 sec max.
• Infrared: 260°C, 30 sec max.

2.6

3.0

(0.102)

(0.118)

4.0

(0.157)

8.6

(0.338)

Land Pattern

Dimensions

mm

(inches)

Brick

Fuses

6125TD Series, Time Delay

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200%

1 Second Minimum

200%

2-4 Seconds Typical

200%

60 Seconds Maximum

SPECIFICATIONS

Product

Voltage

Interrupting

DC Cold

Typical

Typical

Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

AC DC

125VAC 60VDC

min.

typ.

max.

I

2

t†

Drop‡

6125TD500mA

125V 60V

50A 50A

.3350 .4025 .4700

0.716

245 mV

6125TD750mA

125V 60V

50A 50A

.2000 .2350 .2700

1.07

250 mV

6125TD1A

125V 60V

50A 50A

.1350 .1680 .2000

2.88

256 mV

6125TD1.5A

125V 60V

50A 50A

.0550 .0630 .0700

2.35

125 mV

6125TD2A

125V 60V

50A 50A

.0380 .0480 .0580

9.45

133 mV

6125TD2.5A

125V 60V

50A 50A

.0280 .0350 .0420

16.2

130 mV

6125TD3A

125V 60V

50A 50A

.0225 .0263 .0300

15.3

97 mV

6125TD3.5A

125V 60V

50A 50A

.0170 .0195 .0220

14.5

95 mV

6125TD4A

125V 60V

50A 50A

.0160 .0185 .0210

38.8

106 mV

6125TD5A

125V 60V

50A 50A

.0115 .0133 .0150

34.4

100 mV

6125TD7A

125V 60V

50A 50A

.0073 .0087 .0100

90.2

99 mV

* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than

50 microseconds, battery source)

** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I

2

t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds)

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.