Before start, A drill, Flat and phillips style (star) screwdriver – LG LFC25765 User Manual

Page 25: Installation instructions, Close the main water source, Requirements, Select the location of the valve, Connecting the water line

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

CONNECTING THE WATER LINE

BEFORE START

The water source is not guaranteed by the refrigerator

manufacturer.

Follow

instructions

carefully

in

order

to

reduce damage.

Air located inside the water pipes can cause hammering
or tapping causing damage to the inner pipes or water

spillage in the inside of the refrigerator. Call a gualified
plumber

to

fix

such

hammering

on

the

connections

before installing the water pipe.

To avoid burn damage or such, never connect refrigerator
to hot water pipes.

If you are to use the refrigerator before connecting it

to the water source, make sure the ice maker is the off

position.

Never attempt to install the ice maker pipes in areas

where room temperature is below freezing point

When using any electrical device (like a drill) during
the installation, make sure device is doubly isolated or

making ground to prevent risk of electrical surge or

discharge.

All installations should be done considering local water
and drainage reguirements.

If

an

inverted

osmosis

water

filtration

system

is

connected to the cold water source, the water hose

installation

is

not

assured

or

guaranteed

by

the

refrigerator

or

automated

ice

maker

manufacturer.

Follow the next instructions carefully to minimize costly

water related damages.

When

having

an

inverted

osmosis

water

filtration

system connected to the cold-water flow, the water
pressure for such system must be at least between

40-60 PSI or 0,27 MPa (2,8 kg f / cm

2

~ 4,2 kg f

/ cm

2

, (2,8 kg • f / cm

2

~ 4,2 kg • f / cm

2

, less than

2 ~ 3 seconds to fill a 7 oz of capacity cup [0,2 liters]).

If the inverted osmosis water filtration system pressure

is less than 21 PSI or 0,14 MPa (1,5 kg • f / cm

2

, more

than four (4) seconds to fill a 7 oz of capacity cup [0,2

liters]):

a) Identify if the sediments filter in the inverted osmosis

system is being blocked. Replace filter if necessary.
b)

Allow inverted osmosis system storage tank to refill

after extensive usage.
c) Call a gualified plumber if the inverted osmosis water

pressure problem continues.

To

determine

how

much

pipe

material

is

needed,

measures

the

distances

between

the

valves

located

behind the refrigerator and the source of water and add

to that

8

feet (2,4 m). Make sure there is sufficient pipe

material to allow the free movement of the refrigerator

from the wall

• A cold water source. Water pressure should be between

0,138 and 0,82 MPa or 20 and 120 PSI for models not
containing water filter and between 0,276 and 0,82

MPa or 40 and 120 PSI for models containing water

filter.

A drill.

Adjustable 1/2" (12,7 mm) key.

Flat and Phillips style (star) screwdriver.

Two 1/4" (6,35 mm) diameter

compression

nuts

with

two

sides to connect the copper
pipe to the refrigerator valve.

If your current copper pipe has some reduction on the

ends, it will be necessary to get and
adaptor

(found

in

hardware

stores)

to connect the water line to the '

refrigerator. It is also possible to cut
such

reductions

with

a

pipe

cutter

and use the compression connections mentioned above.

• Bypass valve to connect to

the cold water line. The valve

must have a water opening ,

with

an

interior

5/32"

(3,46

mm)

diameter

in

the

cold-

water connection point. These
valves can be located in any cold-water connection

package. Before buying make sure such valve meets
local standards and reguirements.

INSTALLATION INSTRUCTIONS
Install the valve to the pipe that you use to drink water.

(Connect only to a potable water source).

0 CAUTION; Con nect to potable water supply only.

1. CLOSE THE MAIN WATER SOURCE
Open the nearest water faucet to let water flow and
empty pipes.

REQUIREMENTS

• 1/4" (6,35 mm) in diameter copper pipe to

connect refrigerator to the water pipe. Make

sure both terminals are cut in

sguared manner.

2. SELECT THE LOCATION OF THE VALVE

Select the location of the valve that will
provide a better access. It is best to

connect

to

a

vertical

pipeline.

When

connecting

to

a

horizontal

pipeline

is

necessary, make the connection in the
lateral

or

upper

area instead

of

the

lower area to prevent accumulation of
sediment

o

n

24

Advertising