Lnp-ortani Safety Inst-uctíons S¡ Guidelines

Risk of Breathing

Risk of

Eiectrical Shock

Risk of

Explosion or Fire

Avoid using the air compressor in confined areas. Always have adequate space
(12 inches) on all sides of the air compressor. Also keep children, pets, and others out
of the area of operation. This air compressor doss not provide breathable air for anyone
or any auxiliary breathing device. Spraying material will always need to be in another
area away from the air compressor to not allow intake air to damage the air compressor
filter,

Never utilize the air compressor in the rain or wet conditions. Any electrical issues
or repairs should be performed by authorized personnel such as an electrician and
should comply with all national and local electrical codes. The air compressor should
also have the proper three prong groundirig plug, correct voltage, and adequate fuse

protection.

Never operate the compressor near combustible materials, gasoline or solvent vapors.

If spraying flammable materials, locate the air compressor at least 20 feet away from

the spray area. Never operate the air compressor indoors or in a confined area.

Risk of Bursting

Always drain the air compressor tank daily or after each use. If the tank develops a leak,

then replace the air compressor. Never use the air compressor after a leak has been
found or try to make any modifications to the tank. Never modify the air compressor's
factory settings which control the tank pressure or any other function.

Specifications

Pump................................................. Oil-lube direct drive

Motor.................................................... 1.0 HP (Induction)
Bore........................................................................... 1.65"
Stroke.........................................................................1,26"
Voltage Single Phase.......................................... 120 VAC

Air Tank Capacity.............................................. 7 Gallons
Cut-in Pressure....................................................... 95 PSI
Cut-out Pressure...................................................125 PSt
SCFM @ 90 PSi........................................................... 2,4
Oil Capacity............................................... 90 ml or 3 oz.

Minimum Circuit Requirement

Glossary

15 Amps Oil Type............................................... SAE 30 Non-detergent

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure

for air delivery.

PSIG:

Pounds per square inch gauge; a unit of measure

for pressure.

ASME:

American Society of Mechanical Engineers.

California Code: Unit may comply with California Code

462 (I) (2)/ (M) (2).

Cut-in Pressure:

The air compressor will automatically

start to refill the tank when the pressure drops
below the prescribed minimum.

Cut-Out Pressure:

The point at which the motor stops

wCen the tank has reached maximum air

pressure.

Code Certification: Products that bear one or more of

the following marks: UL, ULc, ETL, CSA, have

been evaluated by OSHA-certified independent
safety laboratories and meet the applicable
Undenvriters Laboratories Standards for Safety.

Duty Cycle

This is a 50% duty cycle air compressor. Do not run the air compressor more than 30 minutes of one hour. Doing so
could damage the air compressor.