Instaflation & Assembly

The air compressor should be turned off, unplugged from

the power source, the air bled from the tank and the unit
allowed time to cool before any maintenance is performed.

Personal injuries could occur trom moving parts, electrical

sources, compressed air or hot surfaces. The quick
connect assembly must be attached before use. Failure
to assemble correctly could result in leaks and possible
injury. If unsure of assembly instructions or you experience
difficulty in the assembly please call our toll free number
for assistance.

A WARNING

tnstailmg Wheels

The wheels and handle do not provide adequate clearance
stability or support for pulling the unit up and down stairs
or steps. The unit must be lifted or pushed up a ramp.

* •

It may be necessary to brace or support one end of the

air compressor when attaching the wheels, because it will

have a tendency to tip,

Items Needed For Assembly

• 19mm or adjustable w'rench for shoulder bolt
• 17mm or adjustable wrench for nylon lock nut

install one shoulder bolt, washer, and one nut for each

wheel using bolt holes provided in the wheel bracket. The
shoulder bolt will install from the outside of the wheel
through the top bole in the wheel bracket. Tighten securely
with the washer and nut positioned on the inside of the wheel
bracket,

Assembly

1. Remove air compressor, manual, air filter assembly,

and accessories from packaging,

2. Remove the plastic plug from the compressor intake

port,

(see diagram below)

3.

Install the fitter in the compressor intake port.

(see diagram below)

4. Remove the oil fill cap from the crankcase and fill until

the oii reaches the fop of the red dot in the sight glass.
Oil capacity is

3

oz.

{see below)

Use

SAE-30

non-detergent

(API CG/CD heavy duty motor oii). Under extreme cold

weather conditions use SAE-1Q weight oil.

5. Replace the oil cap.

Getting Started-Location of the Air Compressor

The air compressor should always be located in a clean,

dry, and well ventilated environment. The unit should have
at minimum, 12 inches of space on each side. The air intake
filter should be free of any debris or obstructions. Check
the air filter on a daily basis to be sure it is clean and in
working order.

Grounding Instructions

This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock
by providing an escape route lor the electric current.
This product is equipped with a cord having a grounding
wire with an appropriate grounding plug. (See the figure

below.) The plug must be plugged into an outlet that is
property installed and grounded in accordance with all
local codes and ordinances. Check with a qualified
electrician or service personnel if these instructions are
not completely understood or if in doubt as to whether the

tool is properly grounded.

Grounded

XiLitlet

Grounding Pin

k.

Estimated Assembly Time: Approximately 5 minutes

A WARNING

Improper installation of the grounding plug will result in a
risk of electric shock. If repair or replacement of the cord

or plug is necessary, do not connect the grounding wire to

either flat blade terminals. Check with a qualified electrician
or serviceman if the grounding instructions are not
completely understood, or if in doubt as to whether the
product is properly grounded. Do not modify the plug

provided; if it will not fit the outlet, have the proper outlet

installed by a qualified electrician.

This product is for use on a circuit having a nominal rating
of 120 volts and is factory-equipped with a specific electric

cord and plug to permit connection to a proper electric

circuit. Make sure that the product is connected to an
outlet having the same configuration as the plug. No

adapter should be used with this product. If the product

must be reconnected for use on a different type of electric
circuit, qualified service personnel should make the
reconnection.

Extension Cords

Use only a 3-wire extension cord that has a 3-blade

grounding plug, and a 3-slot receptacle that will accept
the plug on the product. Make sure your extension cord
is in good condition. When using an extension cord, be
sure to use one heavy enough to carry the current your
product will draw. Cords must not exceed 25 feet and
No. 12 AWG size must be used. An undersized cord wit!
cause a drop in line voltage resulting in loss of power and
overheating.

Break In Procedures

No break in procedure is required by the user. This
product is factory tested to ensure proper operation and
performance.