Enabling t3 scrambling, Specifying t3 framing, Setting the cable length – Cisco 7300-6T3 User Manual

Page 45: Checking the configuration

Advertising
background image

4-9

Clear Channel 6-Port T3 (DS3) Line Card Installation and Configuration

OL-3449-02

Chapter 4 Configuring the 6T3 Line Card

Checking the Configuration

adtran for connection from a 6T3 line card to an Adtran DSU. Specify digital-link for connection to a
Digital Link DSU (DL3100). Specify kentrox for connection from a 6T3 line card to a Kentrox DSU.
Specify larscom for connection from a 6T3 line card to a Larscom DSU.

Also see the

“Interoperability Guidelines for 6T3 Line Card DSUs” section on page 1-3

for information

regarding DSU feature compatibilities.

Enabling T3 Scrambling

In interface configuration mode, enable T3 scrambling by entering the scramble configuration
subcommand, as in the following example:

Router(config-if)# scramble

Use the no form of this command to restore the default value, disabled.

Note

The local port configuration must match the remote port configuration. For example, if you enable
scrambling on the local port, you must do the same on the remote port.

Also see the

“Interoperability Guidelines for 6T3 Line Card DSUs” section on page 1-3

for information

regarding DSU feature compatibilities.

Specifying T3 Framing

In interface configuration mode, specify T3 framing by entering the framing {c-bit | m23}
configuration subcommand, as in the following example:

Router(config-if)# framing c-bit

Use the no form of this command to return to the default, C-bit framing.

Setting the Cable Length

In interface configuration mode, set the cable length (0 to 450 feet), as in the following example:

Router(config-if)# cablelength 250

Use the no form of this command to return to the default, which is 50 feet.

Checking the Configuration

After configuring the new interface, use the show commands to display the status of the new interface
or all interfaces, and use the ping and loopback commands to check connectivity. This section includes
the following subsections:

Using show Commands to Verify the New Interface Status, page 4-10

DS3 Alarm and Event Detection, page 4-14

Using the ping Command to Verify Network Connectivity, page 4-15

Using loopback Commands, page 4-15

Bit Error Rate Testing, page 4-17

Advertising