EXPOSURE MEASUREMENT-continued

Manual

Shutter

Speed

Selection

When the shutter-speed dial is set to other than the “A”

setting, manual shutter speed selection is provided, with
exposure determination via the “match-needle” method.

To determine the correct exposure using manual speed

selection, perform the following; Switch on the meter

in the usual way and adjust the shutter-speed dial until

the green needle in the exposure meter display aligns
with the desired speed; then, simply adjust the aperture
setting of the lens until the black needle moves to over­

lap the green needle. If deliberate under- or overex­
posure is desired, adjust the controls so that the green

needle is overlapping the next higher number (one-step
underexposure) or the next lower number (one-step

overexposure). Example under- and overexposure indi­
cations are shown on the following page.